Sc4

Author: n | 2025-04-24

★★★★☆ (4.8 / 2958 reviews)

Download iso workshop

SC4 Product Data Sheet: Download : SC4 RC20 Presets (G300 and G500-Series) Download : SC4 RC20 Presets (G700-Series) Download : SC4 RC20 Presest (LA12, SC8, SCP, LA8, LA8-SUB, SC4) Download : SC4 CAD Drawing 2D: Download : SC4 CAD Drawing 3D: Download : CODA Audio Cardioid Deployments: Download

media markt

SC4 Terraformer - SC4 Devotion Forum Archives

Contents Table of Contents Bookmarks Quick Links SC4 Bench LatheUser's Guide and Installation ManualVersion date: 02-09-11Please Read This Manual Carefully Before Operating this Machine.Copyright by Travers Tool Co., Inc., February 20111PDF created with pdfFactory Pro trial versionwww.pdffactory.com Need help? Do you have a question about the SC4 and is the answer not in the manual? Questions and answers Summary of Contents for OTMT SC4 Page 1 SC4 Bench Lathe User’s Guide and Installation Manual Version date: 02-09-11 Please Read This Manual Carefully Before Operating this Machine. Copyright by Travers Tool Co., Inc., February 2011 PDF created with pdfFactory Pro trial version www.pdffactory.com... Page 2: Table Of Contents Table of Contents IMPORTANT SAFETY INSTRUCTIONS..................... 4 Lathe Features........................... 5 Welcome ............................6 User Manual ............................ 6 Capabilities of the Lathe ........................6 Setting up the Lathe .......................... 7 Electrical Requirements ........................7 Lifting the Lathe ..........................7 Bench Mounting..........................8 Machine Cleanup.......................... Page 3 Cutting Tool Selection........................22 Setting the Tool Height ........................23 Quick Change Tool Posts ......................24 Positioning the Tool ........................24 Rotational Speed Selection......................25 Facing a Workpiece ........................25 Cleaning up a Facing Cut....................... 27 Facing with Power Feed ........................ 27 Center Drilling a Workpiece ...................... Page 4: Important Safety Instructions IMPORTANT SAFETY INSTRUCTIONS Common sense and caution are factors which cannot be built into any product. These factors must be supplied by the operator. PLEASE REMEMBER: 1. When using electric tools, machines or equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and personal injury. 2. Page 5: Lathe Features SC4 Product Data Sheet: Download : SC4 RC20 Presets (G300 and G500-Series) Download : SC4 RC20 Presets (G700-Series) Download : SC4 RC20 Presest (LA12, SC8, SCP, LA8, LA8-SUB, SC4) Download : SC4 CAD Drawing 2D: Download : SC4 CAD Drawing 3D: Download : CODA Audio Cardioid Deployments: Download SC4 Terrain Twintown 915 kb Download : SC4 Terrain Rock Island 427 kb Make a donation : SC4 Terrain Sea Village 915 kb Make a donation : SC4 Terrain Vulcano Ville 427 kb Make a donation : SC4 Terrain Blue Mountain 915 kb Make a donation : SC4 Terrain Riverside 427 kb T H S E R A N U A L POWER4-HUB ONNECTIONS IPC-5 75VDC 24VDC Bus Supply Aux. Supply 75VDC Bus Out 75VDC Bus Input/ Power Hub Passthrough 75VDC Bus Out (x4) AC Source... Page 38: Connections: Two Power4-Hubs - S C U . 1 . 3 6 L E A R A T H S E R A N U A L POWER4-HUB ONNECTIONS Two POWER4-HUBs powering 8 ClearPath-SC motors . (585) 784-7454 EKNIC... Page 39: Auxiliary (24V) Logic Power Supply - S C U . 1 . 3 6 L E A R A T H S E R A N U A L (24V) L UXILIARY OGIC OWER UPPLY The Power Hub and SC Hub each require 24VDC to function. (This is labeled as "24VDC Aux. Page 40: Power4-Hub Leds - S C U . 1 . 3 6 L E A R A T H S E R A N U A L POWER4-HUB LED POWER OVERLOAD OVERTEMP DROPOUT AUX-SHDN POWER4-HUB LEDs LED Name Color LED On Indicates LED Off Indicates Aux. Page 41: Communication And I/O (The Sc4-Hub) SC4-HUB) OMMUNICATION AND NTRODUCTION The SC Hub (Teknic part number SC4-HUB) is the center of communication and I/O routing for all ClearPath-SC systems. The SC Hub links the application computer and I/O devices to your ClearPath-SC motors. Up to four SC Hubs can be linked together to create systems of 16 motors on a single USB or RS-232 port. Page 42: Parts Of An Sc4-Hub - S C U . 1 . 3 6 L E A R A T H S E R A N U A L SC4-HUB ARTS OF AN Global Stop Global Stop Input 24V Input/Passthrough OPEN GLOBAL STOP 24V Power Brake 0 LED Motor Data... Page 43: Clearpath I/O Connector LEAR ONNECTOR This connector sends communication and input signals from the SC Hub to the ClearPath-SC motor. The required cable is a straight-through, 8-pin to 8-pin Molex MiniFit Jr. cable (Teknic P/N: CPM-CABLE-CTRL- MU120). LOOP EADERS Place a jumper block on the 2-pin header associated with the last motor connected to your SC Hub. Page 44: Input Aandb Connectors Cables used for SC inputs can be a maximum of 100 feet (30 m) long. However, longer cable runs may be possible if the cable stock is of high quality, low capacitance, twisted pair construction. Contact Teknic if you need input cables longer

Comments

User3955

Contents Table of Contents Bookmarks Quick Links SC4 Bench LatheUser's Guide and Installation ManualVersion date: 02-09-11Please Read This Manual Carefully Before Operating this Machine.Copyright by Travers Tool Co., Inc., February 20111PDF created with pdfFactory Pro trial versionwww.pdffactory.com Need help? Do you have a question about the SC4 and is the answer not in the manual? Questions and answers Summary of Contents for OTMT SC4 Page 1 SC4 Bench Lathe User’s Guide and Installation Manual Version date: 02-09-11 Please Read This Manual Carefully Before Operating this Machine. Copyright by Travers Tool Co., Inc., February 2011 PDF created with pdfFactory Pro trial version www.pdffactory.com... Page 2: Table Of Contents Table of Contents IMPORTANT SAFETY INSTRUCTIONS..................... 4 Lathe Features........................... 5 Welcome ............................6 User Manual ............................ 6 Capabilities of the Lathe ........................6 Setting up the Lathe .......................... 7 Electrical Requirements ........................7 Lifting the Lathe ..........................7 Bench Mounting..........................8 Machine Cleanup.......................... Page 3 Cutting Tool Selection........................22 Setting the Tool Height ........................23 Quick Change Tool Posts ......................24 Positioning the Tool ........................24 Rotational Speed Selection......................25 Facing a Workpiece ........................25 Cleaning up a Facing Cut....................... 27 Facing with Power Feed ........................ 27 Center Drilling a Workpiece ...................... Page 4: Important Safety Instructions IMPORTANT SAFETY INSTRUCTIONS Common sense and caution are factors which cannot be built into any product. These factors must be supplied by the operator. PLEASE REMEMBER: 1. When using electric tools, machines or equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and personal injury. 2. Page 5: Lathe Features

2025-04-22
User2773

T H S E R A N U A L POWER4-HUB ONNECTIONS IPC-5 75VDC 24VDC Bus Supply Aux. Supply 75VDC Bus Out 75VDC Bus Input/ Power Hub Passthrough 75VDC Bus Out (x4) AC Source... Page 38: Connections: Two Power4-Hubs - S C U . 1 . 3 6 L E A R A T H S E R A N U A L POWER4-HUB ONNECTIONS Two POWER4-HUBs powering 8 ClearPath-SC motors . (585) 784-7454 EKNIC... Page 39: Auxiliary (24V) Logic Power Supply - S C U . 1 . 3 6 L E A R A T H S E R A N U A L (24V) L UXILIARY OGIC OWER UPPLY The Power Hub and SC Hub each require 24VDC to function. (This is labeled as "24VDC Aux. Page 40: Power4-Hub Leds - S C U . 1 . 3 6 L E A R A T H S E R A N U A L POWER4-HUB LED POWER OVERLOAD OVERTEMP DROPOUT AUX-SHDN POWER4-HUB LEDs LED Name Color LED On Indicates LED Off Indicates Aux. Page 41: Communication And I/O (The Sc4-Hub) SC4-HUB) OMMUNICATION AND NTRODUCTION The SC Hub (Teknic part number SC4-HUB) is the center of communication and I/O routing for all ClearPath-SC systems. The SC Hub links the application computer and I/O devices to your ClearPath-SC motors. Up to four SC Hubs can be linked together to create systems of 16 motors on a single USB or RS-232 port. Page 42: Parts Of An Sc4-Hub - S C U . 1 . 3 6 L E A R A T H S E R A N U A L SC4-HUB ARTS OF AN Global Stop Global Stop Input 24V Input/Passthrough OPEN GLOBAL STOP 24V Power Brake 0 LED Motor Data... Page 43: Clearpath I/O Connector LEAR ONNECTOR This connector sends communication and input signals from the SC Hub to the ClearPath-SC motor. The required cable is a straight-through, 8-pin to 8-pin Molex MiniFit Jr. cable (Teknic P/N: CPM-CABLE-CTRL- MU120). LOOP EADERS Place a jumper block on the 2-pin header associated with the last motor connected to your SC Hub. Page 44: Input Aandb Connectors Cables used for SC inputs can be a maximum of 100 feet (30 m) long. However, longer cable runs may be possible if the cable stock is of high quality, low capacitance, twisted pair construction. Contact Teknic if you need input cables longer

2025-04-05
User4842

The box. And, Teknic backs up each ClearPath-SC motor with a three year warranty. . (585) 784-7454 EKNIC... Page 23: Parts Of A Clearpath-Sc Motor - S C U . 1 . 3 6 L E A R A T H S E R A N U A L -SC M ARTS OF A LEAR OTOR ClearPath I/O Connector (Molex Minifit Jr. 8 position) Diagnostic Port DC Bus Power Connector (USB micro-B) Auxilliary PE... Page 24: Example Clear Path -Sc Systems - S C U . 1 . 3 6 L E A R A T H S E R A N U A L -SC S XAMPLE LEAR YSTEMS The ClearPath-SC system was created with both design flexibility and expandability in mind. This section shows a few examples of systems that can be built with ClearPath-SC components. Page 25: Medium System (Single Port, 3 Sc4-Hubs) - S C U . 1 . 3 6 L E A R A T H S E R A N U A L , 3 SC4-HUB EDIUM YSTEM INGLE Motion related sensors & signals (connected through to each motor) E-stop circuit Safety Controls... Page 26: Large System (Multiple Ports And Sc4-Hubs) - S C U . 1 . 3 6 L E A R A T H S E R A N U A L SC4-HUB ARGE YSTEM ULTIPLE ORTS AND Motion related sensors & signals (connected through to each motor) E-stop circuit Safety Controls... Page 27: Powering A Clear Path -Sc So, selecting a power supply often begins with an educated guess followed by real-world testing. If you need to power several motors running at high speed and high torque, consider trying a Teknic IPC-5, 75VDC power supply. Start with one supply but keep in mind that you can add another supply later if your application requires more power. Page 28: Considering A "Lower Voltage" Bus Power Supply - S C U . 1 . 3 6 L E A R A T H S E R A N U A L "L " B ONSIDERING A OWER OLTAGE OWER UPPLY ClearPath-SC motors do work with DC bus power supplies down to 24VDC, but the supply must have sufficient voltage, current, and capacitance to meet your system's torque and speed requirements. Page 29: Additional Power Supply Considerations Engineer's Note: It is very common for machine requirements to change during the development cycle

2025-04-21
User3325

Page 104: Sc4-Hub Specifications 1 0 4 - S C U . 1 . 3 6 L E A R A T H S E R A N U A L SC4-HUB S PECIFICATIONS USB Standard USB 2.0 w/hub, USB 1.1 direct Power Draw If 24V is present, 0.4mA max If 24V is not present, 150mA max. Page 105: Appendix E: Grounding And Shielding 1 0 5 - S C U . 1 . 3 6 L E A R A T H S E R A N U A L E: G PPENDIX ROUNDING AND HIELDING (PE) C ROTECTIVE ARTH ONNECTION Compliance Note: ClearPath-SC must be properly connected to the machine’s Protective Earth terminal to meet EMC emissions specification EN-61000-6-4, and EMC immunity specification EN-61000-6-2, as well as EMC electrical safety specification EN-61010 (for CE/UL compliance). Page 106: Power Returns 1 0 6 - S C U . 1 . 3 6 L E A R A T H S E R A N U A L OWER ETURNS Never use the machine frame or chassis as a power return. Use •... Page 107: Appendix F: Circuit Schematics 1 0 7 - S C U . 1 . 3 6 L E A R A T H S E R A N U A L F: C PPENDIX IRCUIT CHEMATICS All schematics in this section are functionally accurate. Certain advanced circuit elements have been omitted for clarity. Page 108: Sc4-Hub Schematic (Simplified) 1 0 8 - S C U . 1 . 3 6 L E A R A T H S E R A N U A L SC4-HUB S CHEMATIC SIMPLIFIED ClearPath 0 ClearPath 0 Data input indicator Data input indicator Data to ClearPath ->... Page 109 1 0 9 - S C U . 1 . 3 6 L E A R A T H S E R A N U A L Global Stop Input Global Stop Input DTR Brake 0 DTR Brake 0 BAS21 BAS21 BAS21 BAS21... Page 110: Appendix G: Wiring The Inputs 1 1 0 - S C U . 1 . 3 6 L E A R A T H S E R A N U A L G: W PPENDIX IRING THE NPUTS Each ClearPath-SC motor has two available inputs (Input A and B). Inputs are wired to the SC Hub and passed to the motor via the ClearPath I/O

2025-03-25
User8476

The Molex 8-pin connector end can be plugged directly into a Teknic controller, such as ClearCore, ClearLink, or the SC4-HUB (ClearPath-SC). The 8-pin Molex connector can also be cut off to create flying leads to wire into any 3rd party control device (e.g. switches, buttons, PLCs, etc.).CPMS-CABLE-CTRL-AA660Controller Cable, IP67/66K ClearPath, 55 ftPart Number: CPMS-CABLE-CTRL-AA660Connectors: 8-pin M12 A-code to 8-pin M12 A-codeLength: 16.76 m (55 ft)Controller cable designed to connect your digital control signals to your IP67/66K ClearPath motor. This cable comes with M12 A-code connectors on both ends and is designed to be modified (cut to length). The M12 connector end is plugged directly into the ClearPath motor while the flying leads end would be terminated into your 3rd party control device (e.g., switches, buttons, microcontrollers, or PLCs). If you terminate the flying leads end with an 8-pin Molex, this would be compatible with Teknic's ClearCore, ClearLink, or SC4-HUB.CPM-CABLE-USB-120ABUSB Cable, SC4-HUB to USB PortPart Number: CPM-CABLE-USB-120ABConnectors: USB 2.0 A to BLength: 3.05 meters (10 ft)Cable used to connect your host PC to 1) a ClearPath-SC communication hub (e.g., SC4-HUB), or 2) an AC input ClearPath. Note: this cable cannot be used with ClearPath-MC or -SD series models with DC power input; for those, use CPM-CABLE-USB-120 (which has a micro-B connector).MPC023-24-001-TNEMA 23 Power-Off BrakePart Number: MPC023-24-001-TVoltage Requirement: 24 VDCCurrent Draw: 0.31 AmpsOutput Torque: 0.5 Nm holding torqueMax Input Speed: 6000 RPMInput Shaft Diameter: 0.375inMore 24V Spring-applied, power-off brake compatible with NEMA 23 ClearPath motors. One of the most common applications for power-off brakes is on "z-axis" (vertically oriented) mechanical assemblies. Without a brake, highly efficient, backdrivable mechanics will generally fall or crash due to gravity when the motor's power stage is turned off or disabled for any reason.MPC034-24-003-TNEMA 34 Power-Off BrakePart Number: MPC034-24-003-TVoltage Requirement: 24 VDCCurrent Draw: 0.41 AmpsOutput Torque: 1.68 Nm holding torqueMax Input Speed: 6000 RPMInput Shaft Diameter: 0.50inMore 24V Spring-applied, power-off brake compatible with NEMA 34 ClearPath motors. One of the most common applications for power-off brakes is on "z-axis" (vertically oriented) mechanical assemblies. Without a brake, highly efficient, backdrivable mechanics will generally fall or crash due to

2025-03-31

Add Comment